<aside>
💡 EKG reading
- Calibration (voltage and speed): standard:
- Paper/tracing speed = 25 mm/second
- 1 mm (horizontal) = 0.04 second
- 1 mm (vertical) = 0.1 mV
- Calculate heart rate:
- Calculation: divide 300 by the number of large squares between RR intervals
- Normal heart rate: 60–100/min
- Determine rhythm: normal sinus rhythm criteria:
- Normal P-wave morphology
- A regular QRS complex follows every P wave
- Normal, constant PR/RR intervals
- Determine timing intervals (PR, QRS, QTC):
- Manual calculation by measuring horizontal blocks
- Electronic calculation by machine/software (usually listed in the top-left corner)
- PR interval 0.12–0.2 second
- QRS complex < 0.12 second
- QTC interval 0.30–0.46 second
- Determine mean QRS axis:
- Direction of QRS deflection:
- Positive: The mean electrical vector travels towards the positive electrode in a given lead.
- Negative: The mean electrical vector travels away from the positive electrode in a given lead.
- Normal: -30°–100°
- Normally positive in lead II and lead aVF
- Evaluate P-wave morphology by voltage size and deflection:
- Normal time < 0.12 second
- Normally upright in lead II and lead aVF
- Evaluate QRS morphology and/or voltage:
- Normal duration < 0.12 second
- R wave should transition in amplitude in the precordial leads:
- Lowest voltage in V1, Highest voltage in V6
- Evaluate ST-segment and T-wave morphology:
- ST segment:
- Flat, isoelectric segment after QRS complex, but before T wave
- Normally no depression or elevation
- T wave: normally concordant with QRS complex
- Compare with prior tracings if available.
</aside>
EKG 실습
Access - Epicardio
Hativ - 뷰노, View the Invisible, Know the Unknown
하티브 P30 측정 방법
1. 사지 유도(RA, LA, RL, LL)를 부착 후 심전도를 촬영하십시오.
- RL lead → RL doesn't come up in ECG readings, and is considered as a grounding lead that helps minimize ECG artifact.
2. 사지 유도를 잘못 연결했을 때 촬영한 심전도를 확인하고 정상 심전도와 비교하여 그 특징과 심전도가 그렇게 나온 이유를 설명하십시오.